Chapter 3: AT Commands Reference
August 5, 2008 AT Commands Reference Manual 3-221
The following table shows the +MIOC parameters.
Table 3-143: +
MIOC Parameters
<Parameter> Description
<pin selection> Selected pins for the action invoked. This is a binary vector in which each bit points to
pin number. Vector size is 8.
0 Not selected
1 Selected pin (default)
<data vector> This is a binary vector in which each bit show the physical value of pin. Data vector
size is 8.
0 Physical low signal.
1 Physical high signal (default).
The default value:
On Power Up - as previously saved in FLEX bytes.
Before set command first used with <Data vector> and <Mode>=0, or after +MIOC
without <Data vector> and before +MIOC command used - 1.