Motorola AT Commands G24-L Informazioni Techniche Pagina 242

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 680
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 241
Email
3-154 AT Commands Reference Manual August 5, 2008
6. If the operation (send or receive) will proceed, or not, after security warning alert presence.
Note: +MEMGS parameters are saved after the power cycle.
The following table shows the +MEMGS parameters.
Command
Type
Syntax Response/Action Remarks
Set
AT+MEMGS=[<save_srv>[,
<size>
[,<auto_sign>],[
security_ssl_sending],[
security_ssl_receiving],[
security_warning_backgrou
nd_process]
OK
Or:
+CME ERROR: <err>
Read
AT+MEMGS? +MEMGS=<save_srv>,<si
ze>,<auto_sign>>,<securit
y_ssl_sending>,<
security_ssl_receiving>,<
security_warning_backgro
und_process>
OK
Test
AT+MEMGS=? +MEMGS: list of
supported <save_srv>s
values, list of supported
<size>s values, maximum
allowed length of
<auto_sign>, list of
supported <
security_ssl_sending>s
values, list of supported <
security_ssl_receiving >s
values,
list of supported <
security_warning_backgro
und_process>s values
OK
Table 3-91: +MEMGS Parameters
<Parameter> Description
<save_srv> Allows the user to retain a copy of the messages on the server, default value is 0
which means messages will be saved on server after downloading.
Possible values
:
0 - Save on server
1 - Delete from server
<size> Incoming email size restriction. The default is 10240 byte. The range is 0-65535. 0 is
a valid value. In this case device will not receive email messages.
<auto_sign> Auto signature. String field for entering auto signature information. The maximum
length is 100 characters. Auto signature will be added to email body when ever it
exist.
Vedere la pagina 241