PTP SOLUTIONS GUIDE
26
Installation with PTP 400 and PTP 600 Series Radios:
For the best possible protection, each PTP 400 and PTP 600 radio requires two Lightning Protection Units
(PTP-LPUs), one installed adjacent to the radio on the wall, tower or mast, and one installed at the cable
entry point of the building in which the network resides. The following are main installation configurations
that can be deployed with the Motorola PTP 400 and PTP 600 Series wireless Ethernet bridges:
Tower/mast/wall configuration – uses two PTP-LPU units with each PTP 400 or PTP 600 radio
Tower/mast/wall configuration with T1/E1 – uses two PTP-LPU units per radio and two additional
PTP-LPU units per T1/E1
Tower/mast/wall configuration with a Memorylink UltraSync™ GPS-100M Synchronization Unit –
uses two PTP-LPU units per radio
Tower/mast/wall configuration with T1/E1 and an UltraSync GPS-100M – uses two PTP-LPU units per
radio plus two additional PTP-LPU units per T1/E1
Product Requirements:
Maximum Cable Lengths
> Ground connection: < 2 ft (0.6 meters)
> Upper tower grounds: within 1 ft (0.3 meters) of the ODU bracket and on the same metal
When connected to the back of an ODU, the minimum pole diameter required is 2.5 inches (6.35 cm)
Grounding stake (included)
Installation with PTP 500 Series Radios:
Because PTP 500 radios have built-in lightning protection capability, there is no need to deploy an external
lightning protection device on a tower or wall adjacent to the radio. The lightning protection built into the
PTP 500 radio contains all the protection required at the top of the tower or wall. However, an external
PTP-LPU is required near the base of the tower or wall at the cable entrance point leading to the network.
The Motorola PTP 500 LPU End Kit contains one lightning protection unit for use as the external unit to be
installed near the base of the tower or wall. Together the lighting protection built into the PTP 500 radio and
the external PTP-LPU offer excellent protection from the harmful effects of lightning.
For detailed installation instructions, refer to the PTP-LPU User Manual.
PTP-LPU Product Description continued
PTP Lightning Protection Unit
mounted on a tower or mast
with a PTP 400 or PTP 600
Series radio
Note: Motorola strongly recommends purchasing
the Motorola wi4 Fixed PTP Lightning Protection
Unit (PTP-LPU) as an integral part of a PTP link,
excluding PTP 100 Series links. While purchasing the
Motorola PTP Link Guard All Risk Extended Warranty
will cover the cost of replacing a radio damaged by
lightning, deploying lightning protection initially will
help the operator avoid the delays and costs associ-
ated with taking down damaged radios and installing
replacement units. When correctly installed, the
Motorola PTP Lightning Protection Unit gives the
PTP radio the best protection from the harmful
effects of lightning. However, 100% protection is
neither implied nor possible.