Pagina 1 - User’s Manual

MVME712-10Transition ModuleUser’s Manual (MVME712-10/D1)

Pagina 3

MVME712-10/D1 1-1 1 GENERAL INFORMATION Introduction This manual provides general information, hardware preparation, installation instructions, and s

Pagina 4

General Information 1-2 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual1 Specifications The MVME712-10 specifications are given in

Pagina 5

Specifications MVME712-10/D1 1-31 Cooling Requirements Motorola VMEmodules are specified, designed, and tested to operate reliably with an incoming a

Pagina 6 - Related Documentation

General Information 1-4 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual1 For minimum RF emissions, it is essential that the condi

Pagina 7 - Contents

Cables Required MVME712-10/D1 1-51 Figure 1-1. MVME712-10 Transition Module with MVME166100-pin I/O ConnectorSCSI OutSCSI InMVME712-10MOTOROLAETHERN

Pagina 8 - List of Figures

General Information 1-6 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual1

Pagina 9 - List of Tables

MVME712-10/D1 2-1 2 HARDWARE PREPARATION ANDINSTALLATION INSTRUCTIONS Introduction This chapter provides unpacking instructions, hardware preparation

Pagina 10

Hardware Preparation and Installation 2-2 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2 Figure 2-1. MVME712-10 Connector L

Pagina 11 - GENERAL INFORMATION

MVME712-10 Module Preparation MVME712-10/D1 2-32 Serial Port Configuration The four RJ45 EIA-232-D serial ports are factory configured as terminal (D

Pagina 12 - Specifications

Notice While reasonable efforts have been made to assure the accuracy of this document, Motorola, Inc. assumes no liability resulting from any omissi

Pagina 13 - FCC Compliance

Hardware Preparation and Installation 2-4 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2 Port A bits 7 to 4 are the configurati

Pagina 14 - Cables Required

MVME712-10 Module PreparationMVME712-10/D1 2-52Figure 2-2. MVME712-10 Serial Port Configured as DCE (to Terminal)CTSDTRRTSDSRDCDRXDTXDTXCIRXCIRXCO2401

Pagina 15 - MVME712-10/D1

Hardware Preparation and Installation2-6 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2Figure 2-3. MVME712-10 Serial Port Config

Pagina 16 - General Information

MVME712-10 Module PreparationMVME712-10/D1 2-72Figure 2-4. MVME712-10 Configuration RegisterHIH2H3H4PB0PB1PB2PB3PB4PB5PB6PB7PA0PA1PA2PA3PA4PA5PA6PA7SG

Pagina 17 - INSTALLATION INSTRUCTIONS

Hardware Preparation and Installation2-8 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2Installation InstructionsInstallation of

Pagina 18 - PRIMARY SIDE

Installation InstructionsMVME712-10/D1 2-92Front Chassis Mount, External SCSI DevicesTo mount the MVME712-10 in the front of the chassis with external

Pagina 19 - Serial Port Configuration

Hardware Preparation and Installation2-10 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2Figure 2-5. Typical MVME712-10 Installa

Pagina 20

Installation InstructionsMVME712-10/D1 2-112Front Chassis Mount, Internal SCSI DevicesTo mount the MVME712-10 at the front of the chassis with interna

Pagina 21 - MVME712-10/D1 2-5

Hardware Preparation and Installation2-12 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2Figure 2-6. Typical MVME712-10 Installa

Pagina 22

Installation InstructionsMVME712-10/D1 2-132Rear Chassis Mount, Internal SCSI DevicesTo mount the MVME712-10 at the rear of the chassis with internal

Pagina 23 - MVME712-10/D1 2-7

Safety SummarySafety Depends On You The following general safety precautions must be observed during all phases of operation, service, and repair of

Pagina 24 - Installation Instructions

Hardware Preparation and Installation2-14 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual2Figure 2-7. Typical MVME712-10 Installa

Pagina 25 - MVME712-10/D1 2-9

MVME712-10/D13-13SUPPORT INFORMATIONIntroductionThis chapter provides the interconnection signals, parts lists with parts location illustrations, and

Pagina 26 - ETHERNETPARALLEL/PRINTER PORT

Support Information3-2 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual3EIA-232-D Connectors J1, J2, J3, and J4Connectors J1, J2, J

Pagina 27 - MVME712-10/D1 2-11

Interconnect SignalsMVME712-10/D1 3-33SCSI Connectors J5 and J7Connectors J5 and J7 are identical; two connectors are provided for convenience of acce

Pagina 28

Support Information3-4 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual3SCSI Connector J6Connector J6 is a high-density 16-bit-wide

Pagina 29 - MVME712-10/D1 2-13

Interconnect SignalsMVME712-10/D1 3-53Printer/Parallel Connector J8Connector J8 is the Printer/Parallel port on the MVME712-10. Each pin connection, s

Pagina 30 - 1136 9309

Support Information3-6 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual3 I/O Connector J9Connector J9 on the MVME712-10 is used to

Pagina 31 - SUPPORT INFORMATION

Interconnect SignalsMVME712-10/D1 3-7320 PRACK* DATA ACKNOWLEDGE (Printer) - a low level input pulse indicating that the next character may be sent.2

Pagina 32

Support Information3-8 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual332 SCTS1 CLEAR TO SEND (serial port 1) - CTS is a func-tion

Pagina 33 - SCSI Connectors J5 and J7

Interconnect SignalsMVME712-10/D1 3-9342 SRXCO2B RECEIVE CLOCK OUT (serial port 2) - this line can be conÞgured to clock input data from a ter-minal t

Pagina 34 - SCSI Connector J6

The computer programs stored in the read only memories of this device contain material copyrighted by Motorola, Inc., Þrst published 1988, and may be

Pagina 35 - Printer/Parallel Connector J8

Support Information3-10 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual353 SRTS3B REQUEST TO SEND (serial port 3) - RTS is sup-pl

Pagina 36 - I/O Connector J9

Interconnect SignalsMVME712-10/D1 3-11363 SRXCI3 RECEIVE CLOCK IN (serial port 4) - this line can be conÞgured to clock input data from a terminal to

Pagina 37 - MVME712-10/D1 3-7

Support Information3-12 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual372 SCD4 DATA CARRIER DETECT (serial port 4) - sent by the

Pagina 38

Interconnect SignalsMVME712-10/D1 3-133Ethernet Connector J10Connector J10 is the Ethernet port on the MVME712-10. Each pin connection, signal mnemoni

Pagina 39 - MVME712-10/D1 3-9

Support Information3-14 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual3Parts ListThe components of the MVME712-10 are listed in T

Pagina 40

Parts ListMVME712-10/D1 3-153R7,R11,R36 51NW9635A13 Resistor, 16-pin, 8-22 ohmR15-R19,R38,R42-R47,R49, R5006SW-965A11 Resistor, SMD, 4.7K ohm, 1/8 W,

Pagina 41 - MVME712-10/D1 3-11

Support Information3-16 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual3Figure 3-1. MVME712-10 Parts Location13

Pagina 42

Schematic DiagramMVME712-10/D1 3-173Schematic DiagramThe MVME712-10 schematic diagram is illustrated in Figure 3-2.

Pagina 43 - Ethernet Connector J10

Support Information3-18 MVME712-10 Transition Module and I/O Distribution Set UserÕs Manual3

Pagina 44 - Parts List

IN-19IndexAairflow required 1-3asterisk 3-1Ccable, shielded 3-1cables, user-supplied 1-4, 2-8capacitors 3-14cautions 2-8, 2-9, 2-11, 2-13, 3-1CD2401 2

Pagina 45 - MVME712-10/D1 3-15

Preface The MVME712-10 Transition Module UserÕs Manual provides general information, hardware preparation, installation instructions, and support i

Pagina 46 - Support Information

IndexIN-20INDEXJJ1, J2, J3, J4 signals 3-2J10 signals 3-13J5, J7 signals 3-3J6 signals 3-4J8 signals 3-5J9 signals 3-6jacks, RJ45 1-1, 1-2jacks, telep

Pagina 47 - Schematic Diagram

Related Documentation The Motorola publications listed in the table below are referenced in this document. If not shipped with this product, manuals

Pagina 48

vii Contents Introduction 1-1Features 1-1SpeciÞcations 1-2Cooling Requirements 1-3 FCC Compliance 1-3General Description 1-4Cables Required 1-4Introd

Pagina 49

List of Figures MVME712-10 Transition Module with MVME166 1-5MVME712-10 Connector Locations 2-2MVME712-10 Serial Port ConÞgured as DCE (to Terminal)

Pagina 50

ix List of Tables MVME712-10 SpeciÞcations 1-2EIA-232-D Connectors J1, J2, J3, and J4 Interconnect Signals 3-2SCSI Connectors J5 and J7 Interconnect